Dündar CT 16.2 Centrifugal Fan, Three-Phase, 1,500 m³, 2,700 rpm
$136.46 $189.53 · In stock
Brand: Dündar · SKU: 104162200 · Warranty: 24 months

Other options
- Dündar CM 16.2 Radial Centrifugal Fan Extractor, Single-Phase, 1,500 m³, 2,700 RPM – $137.36
- Dündar CM 16.4 Radial Centrifugal Fan (Single-Phase), 750 m³/h, 1,460 rpm – $128.42
- Dündar CT 16.4 Radial Centrifugal Fan (Three-Phase), 750 m³, 1,470 rpm – $127.52
- Dündar CM 18.2 Radial Centrifugal Fan (Single-Phase), 1,625 m³/h, 2,650 rpm – $163.33
- Dündar CT 18.2 Radial Centrifugal Fan / Aspirator, Three-Phase, 1700 m³, 2770 RPM – $163.33
- Dündar CM 18.4 Centrifugal Fan, Single-Phase, 1,000 m³, 1,430 rpm – $153.35
- Dündar CT 18.4 Radial Centrifugal Fan (Three-Phase), 1,100 m³/h, 1,445 rpm – $153.35
- Dündar CM 21.2 Radial Centrifugal Fan (Single-Phase), 2,500 m³/h, 2,700 rpm – $179.18
- Dündar CT 21.2 Radial Centrifugal Exhaust Fan, Three-Phase, 2,500 m³, 2,700 RPM – $186.83
- Dündar CM 21.4 Radial Centrifugal Fan (Single-Phase), 1,575 m³, 1,390 rpm – $166.03
- Dündar CT 21.4 Radial Centrifugal Fan Extractor, Three-Phase, 1,650 m³, 1,430 RPM – $167.83
Product description
Dündar CT 16.2 Specifications
|
Product Type |
V |
AC/DC |
~ |
Weight |
W |
Sound |
rpm |
m3/h |
|
CT 16.2 |
380 |
AC |
3 |
8 |
540 |
70 |
2700 |
1500 |
| MODEL | C | D | E | H | L | O | P | S | T |
| CT 16.2 | 310 | 180 | 280 | 300 | 142 | 140 | 110 | 130 | 145 |
What Is a Radial Fan?
Fans that generate a pressure difference are called radial fans. The resulting air effect acts in the direction of centrifugal force. A centrifugal fan is a mechanical device used to move air or other gases. Like a pump, these fans have a rotating impeller and a spiral-shaped housing in which the impeller sits. Air or gas enters axially through the center, is pressurized and discharged tangentially from the impeller periphery into ducts, and is expelled through the outlet. Due to the high pressure they generate, centrifugal fans are ideal for high-pressure applications such as drying and air conditioning systems. Since all moving parts are enclosed, they also have particle-reducing properties that make them ideal for use in air pollution control and filtration systems.Radial Fan Applications
- Where the pressure and flow rates of axial fans are insufficient,
- In duct applications,
- In solid-fuel central heating boilers,
- Hot air extraction in high-temperature environments, general and industrial buildings,
- Warehouses, stockrooms, and storage facilities,
- Garages and publicly accessible buildings, agricultural buildings,
- Commercial greenhouses,
- Large workshops,
- Paint shops,
- Factories,
- Environments with dust and vapor,
- Cooling of industrial machinery
- (Welding machines, transformers, compressors…)
Radial Fan Casings and Impellers
- Radial casing made from cold-drawn high-quality DKP sheet metal,
- High corrosion resistance with environmentally friendly electrostatic epoxy powder coating; galvanized forward-curved radial impeller dynamically tested per ISO 1940 standard; manufactured in accordance with EN 60335-2-80
- High pressure and flow rate values through inlet nozzle application,
- Air inlet is protected by a guard against foreign object entry *
- Sturdy and neat casing structure with special clinch-type casing assembly,
- Low noise level,
- Right- and left-hand orientation options for installation in any desired direction,
Radial Fan Motors
- Quality production without manual handling on high-technology CNC machines,
- Aluminum-finned motor casing with high thermal conductivity,
- Rotor balanced to ISO 1940 standards for extended bearing service life,
- Wide operating range for coils with insulation class F: −40° to +70°;* 230 V / 50 Hz single-phase fan motor **
- 400 V / 50 Hz, three-phase fan motor
- Standards-compliant certified components,
- IP 54 protection class (IP 55 production option available on request)
- Variable frequency drive (VFD) control can be used with three-phase fans ***
Things to Consider When Selecting a Fan;
4 parameters should be considered when selecting a fan:- Required Air Flow Rate
- Pressure Losses
- Acceptable Noise Level
- Electrical Power Connection Type
| Environment | Air Change Rate |
| Auditoriums | 6-8 |
| Paint Ovens | 25-50 |
| Vault Rooms | 3-6 |
| Cinemas and Theaters | 5-8 |
| Commercial Kitchens | 15-30 |
| Foundries | 8-15 |
| Gymnasiums | 4-6 |
| Laundries | 10-20 |
| Indoor Swimming Pools | 3-4 |
| Restaurants | 8-12 |
| Conference Rooms | 6-8 |
| Waiting Rooms | 4-6 |
| Copy Rooms | 10-15 |
| Machine Rooms | 10-40 |
| Shops | 4-8 |
| Dry Cleaning | 5-15 |
| General Manufacturing Areas | 4-8 |
| Hospitals | 8-12 |
| Laboratories | 8-15 |
| Normal Activity (non-smoking) | 29 m³/h |
| Normal Activity (smoking) | 58 m³/h |
| Light Activity | 45 m³/h |
| Heavy Activity (industrial work areas) | 60 m³/h |
The amount of air per person in living and working spaces depending on activity level can help determine the required air flow rate.
Based on the information provided above, the required air flow rate is determined as follows.
- Q [ m³/h ] = Air change rate coefficient (1 hour) × Space volume (m³) Or
- Q [ m³/h ] = Number of people × Air flow rate required per person
Fan selection is also made based on this flow rate requirement.
After completing the flow rate calculations, the installation location of the fan should be determined. Where will the fan be mounted — ceiling, wall, chimney, or ventilation duct? Another consideration is the voltage of the electrical supply to the fan. Continuing with our office example: fans in offices are generally mounted on a wall or glass. If a domestic electricity supply is used, a single-phase fan should be preferred. If it is to be used in an industrial setting, a fan operating on three-phase (380 V) power should be used.Specifications
| Brand | Dündar |
|---|
Similar products
- Modern Teknik Axial Chimney and Wall Exhaust Fan, 25 cm, 220V, 1,500 RPM, 1,500 m³/h – $203.76
- Nano Water Filter, 1 Inch – $171.69
- Fansan Decorative White Bathroom and Toilet Glass and Window Ventilation Fan – $10.62
- Aircol 20 K Shuttered Axial Fan / Extractor, 360 m³/h – $34.03
- Modern Teknik 0.5 HP Low-Pressure Open-Blade Centrifugal Fan, 45 mmWG, 2,000 m³/h – $485.23
- Aircol 100 mm Duct Inline Round Fan 390 m³/h 2300 rpm - Aircol 100 KF – $48.17
- Raksan Smart ABS Plastic Marine Anemostaat, 100 mm – $4.61
- Dündar MF 280 Axial Fan (EBMPAPST W2E250-HL06-01 Compatible), 280x280x85 mm, 230 V – $94.17
- 65 cm Industrial Pedestal Fan 65 cm – $111.75
- Aircol 150C MP Glass and Wall-Mount Axial Fan – $31.84
More products in Centrifugal and Radial Fans · All Dündar products