Yurtfan AB-25HP Low-Pressure Centrifugal Fan, 35,000 m³/h, 210 mmWG
Request a quote: 0531 565 11 25. · Out of stock
Brand: Yurtfan · SKU: AB025HP


Other options
- Yurtfan AB-0.5HP Low-Pressure Centrifugal Fan, 2,000 m³/h, 40 mm w.g. (out of stock)
- Yurtfan AB-1HP Low-Pressure Centrifugal Fan, 3500 m³/h, 45 mmSS (out of stock)
- Yurtfan AB-1.5HP Low-Pressure Centrifugal Fan, 4,300 m³/h, 60 mm WC (out of stock)
- Yurtfan AB-2HP Low-Pressure Centrifugal Fan, 5700 m³/h, 70 mmSS (out of stock)
- Yurtfan AB-3HP Low-Pressure Centrifugal Fan, 7,400 m³/h, 75 mmWG (out of stock)
- Yurtfan AB-4HP Low-Pressure Centrifugal Fan, 8,700 m³/h, 80 mmWG (out of stock)
- Yurtfan AB-5.5HP Low-Pressure Centrifugal Fan, 10,100 m³/h, 95 mmSS (out of stock)
- Yurtfan AB-7.5HP Low-Pressure Centrifugal Fan, 14,000 m³/h, 120 mm WC (out of stock)
- Yurtfan AB-10HP Low-Pressure Centrifugal Fan, 16,000 m³/h, 150 mmSS (out of stock)
- Yurtfan AB-15HP Low-Pressure Volute Fan, 22000 m³/h, 180 mm (out of stock)
- Yurtfan AB-20HP Low-Pressure Centrifugal Fan, 27,500 m³/h, 200 mm w.g. (out of stock)
- Yurtfan AB-30HP Low-Pressure Centrifugal Fan, 42000 m³/h, 260 mmWG (out of stock)
Product description
What Is a Centrifugal (Snail) Fan?
These are fans in which air leaves the fan wheel at a 90° angle relative to the inlet, departing tangentially along the blades.
The advantages of centrifugal fans are as follows:
- Wide application range
- High-temperature, corrosive, and abrasive environment applications
- Easier access to the motor compared to direct-drive axial fans
- More efficient and quieter operation, especially in locations with variable flow resistance
- High structural stability
- Very high pressures and flow rates
What Is a Low-Pressure Centrifugal Fan? Where Is It Used?
- Low-pressure fans are used for circulating existing air. MTTA low-pressure centrifugal fans have an air flow rate range of 2,000 m³/h to 42,000 m³/h.
- For exhausting small particles, fine dust, or chips,
- For ventilating paint shops and areas where chemicals are used,
- Used in industrial kitchens. Thanks to the square casing system, the casing can easily be rotated to the desired discharge position. It is one of the most economical ventilation solutions.
- The system must be fully designed, with all components and dimensions determined.
- Air volume (flow rate) values must be established.
- Static pressure should be determined by summing the pressure losses across components such as ducts, grilles, louvers, dampers, air washers, filters, heating and cooling coils.
Things to Consider When Selecting a Low-Pressure Radial Fan
- MTTA low-pressure centrifugal fans have an air flow rate range of 2,000 m³/h to 42,000 m³/h.
| MODEL |
VOLTAGE (V) |
HP | kW |
SPEED RPM |
FLOW RATE (m³/h) |
PRESSURE mmWG |
| AB-25HP | 380-400 | 25 |
18.5 |
1500 | 35000 | 210 |
| MODEL | A | B | C | D | E | H1 | H2 | L1 | L2 |
| AB-25HP | 1178 | 1176 | 630 | 400 | 1092 | 710 | 500 | 740 | 530 |
- Required Air Flow Rate
- Pressure Losses
- Acceptable Noise Level
- Electrical Power Connection Type
- Q [ m³/h ] = Air change rate coefficient (1 hour) × Space volume (m³) Or
- Q [ m³/h ] = Number of people × Air flow rate required per person After determining the required air flow rate for the space, an appropriate duct design (taking noise and air velocity criteria into account) should be made and pressure losses calculated. The fan type (axial, radial, roof, smoke extraction, etc.) should be decided based on the operating environment, and the appropriate fan should be selected from the relevant fan curve according to the determined flow rate–static pressure pair. To briefly illustrate the above with an example: an office has 5 employees, a ceiling height of 2.6 meters, and a floor area of 50 m², giving a volume of 2.6 × 50 = 130 m³. The air change rate coefficient given for an office in the table is 4–8; let's take 5. 130 × 5 = 650 m³/h air requirement. If we assume normal activity in the office, 5 people × 29 m³ = 145 m³ for employees, giving a total of 650 + 145 = 795 m³/h air requirement.
Things to Consider When Selecting a Fan;
4 parameters should be considered when selecting a fan:| Environment | Air Change Rate |
| Auditoriums | 6-8 |
| Paint Ovens | 25-50 |
| Vault Rooms | 3-6 |
| Cinemas and Theaters | 5-8 |
| Commercial Kitchens | 15-30 |
| Foundries | 8-15 |
| Gymnasiums | 4-6 |
| Laundries | 10-20 |
| Indoor Swimming Pools | 3-4 |
| Restaurants | 8-12 |
| Conference Rooms | 6-8 |
| Waiting Rooms | Copy Rooms |
| Copy Rooms | 10-15 |
| Machine Rooms | 10-40 |
| Shops | 4-8 |
| Dry Cleaning | 5-15 |
| General Manufacturing Areas | 4-8 |
| Hospitals | 8-12 |
| Laboratories | 8-15 |
| Normal Activity (non-smoking) | 29 m³/h |
| Normal Activity (smoking) | 58 m³/h |
| Light Activity | 45 m³/h |
| Heavy Activity (industrial work areas) | 60 m³/h |
Based on the information provided above, the required air flow rate is determined as follows.
Fan selection is also made based on this flow rate requirement.
After completing the flow rate calculations, the installation location of the fan should be determined. Where will the fan be mounted — ceiling, wall, chimney, or ventilation duct? Another consideration is the voltage of the electrical supply to the fan. Continuing with our office example: fans in offices are generally mounted on a wall or glass. If a domestic electricity supply is used, a single-phase fan should be preferred. If it is to be used in an industrial setting, a fan operating on three-phase (380 V) power should be used.Specifications
| Brand | Yurtfan |
|---|
Similar products
- Modern Teknik Axial Chimney and Wall Exhaust Fan, 25 cm, 220V, 1,500 RPM, 1,500 m³/h – $203.76
- Nano Water Filter, 1 Inch – $171.69
- Fansan Decorative White Bathroom and Toilet Glass and Window Ventilation Fan – $10.62
- Aircol 20 K Shuttered Axial Fan / Extractor, 360 m³/h – $34.03
- Modern Teknik 0.5 HP Low-Pressure Open-Blade Centrifugal Fan, 45 mmWG, 2,000 m³/h – $485.23
- Aircol 100 mm Duct Inline Round Fan 390 m³/h 2300 rpm - Aircol 100 KF – $48.17
- Raksan Smart ABS Plastic Marine Anemostaat, 100 mm – $4.61
- Dündar MF 280 Axial Fan (EBMPAPST W2E250-HL06-01 Compatible), 280x280x85 mm, 230 V – $94.17
- 65 cm Industrial Pedestal Fan 65 cm – $111.75
- Aircol 150C MP Glass and Wall-Mount Axial Fan – $31.84
More products in Low-Pressure Centrifugal (Snail) Fan · All Yurtfan products