Dündar ST 45S Cooled Industrial Exhaust Fan, Three-Phase, 5500 m³, 1420 RPM
$158.98 $220.81 · In stock
Brand: Dündar · SKU: 103454230 · Warranty: 24 months

Other options
- Dündar SM 30S Single-Phase Cooled Industrial Exhaust Fan, 2,300 m³, 1,465 RPM (out of stock)
- Dündar ST 30S Cooled Industrial Extractor Fan, Three-Phase, 2,320 m³, 1,470 RPM (out of stock)
- Dündar SM 35S Single-Phase Cooled Industrial Exhaust Fan, 3,250 m³, 1,435 RPM (out of stock)
- Dündar ST 35S Cooled Industrial Exhaust Fan, Three-Phase, 3,300 m³, 1,450 RPM (out of stock)
- Dündar SM 40S Single-Phase Cooled Industrial Exhaust Fan, 4,500 m³, 1,445 RPM – $143.33
- Dündar ST 40S Cooled Industrial Exhaust Fan, Three-Phase, 4,550 m³, 1,450 RPM – $149.70
- Dündar SM 45S Single-Phase Cooled Industrial Exhaust Fan, 5000 m³, 1410 RPM – $149.35
- Dündar SM 50S Single-Phase Cooled Industrial Extractor Fan, 6,900 m³, 1,420 RPM – $177.37
- Dündar ST 50S Cooled Industrial Exhaust Fan, Three-Phase, 7,100 m³, 1,450 rpm – $182.18
- Dündar SM 60S Single-Phase Cooled Industrial Exhaust Fan 9700 m³ 1400 RPM – $199.70
- Dündar ST 60S Cooled Industrial Exhaust Fan, Three-Phase, 10,100 m³, 1,415 rpm – $205.89
- Dündar ST 70S Cooled Industrial Exhaust Fan, Three-Phase, 13,500 m³, 1,325 rpm – $244.67
Product description
|
Product Type |
V |
AC/DC |
~ |
Hz |
W |
Sound |
rpm |
m3/h |
|
ST 45 S |
380 |
AC |
3 |
50 |
240 |
67 |
1420 |
5500 |
| MODEL | ØA | B | ØC | ØD | E | F |
| ST-45S | 470 | 495 | 525 | 450 | 220 | 125 |
What Is a Cooling Exhaust Fan?
Fans are similar to pumps but, unlike pumps, they pressurize and move gas rather than liquid. Fans are the most important equipment used both for the air intake and discharge functions required by industrial processes and for the ventilation of residential buildings, workplaces, and especially communal living spaces.Industrial equipment operating at high levels generally produces excess heat. These systems may carry a risk of overheating if suitable cooling equipment is not used.
It can create many risks, such as overheated equipment, reduced equipment performance, premature component and lubricant degradation, general system failure, and ultimately the possibility of fire and other safety hazards for users and operating personnel.
Industrial cooling exhaust fans are fans produced to eliminate these risks. They cool the hot air in your facility while enabling your equipment and personnel to operate more efficiently.
Where Are Cooling Exhaust Fans Used?
- Warehouses, stockrooms, and storage facilities,
- Garages and public buildings, agricultural buildings,
- Commercial greenhouses,
- Large workshops,
- Paint shops,
- Factories,
- Environments containing dust and vapor,
- Cooling of industrial machinery (welding machines, transformers, compressors)
Fan Housing and Blade Sections of Cooling Exhaust Fans
- Housing and blade sections manufactured from cold-drawn, high-quality DKP sheet steel,
- High corrosion resistance with environmentally friendly electrostatic epoxy powder coating,
- Impeller blades dynamically tested to ISO 1940 standard,
- Front and rear protection guards conforming to EN 60335-2-80 standards,
- Slim, compact design with motor and impeller takes up 50% less space than comparable models,
- Low Noise Level
Motor of Cooling Exhaust Fans
- High-quality production without manual intervention on high-technology CNC machines,
- Aluminum-finned motor housing with high thermal conductivity,
- Rotor balanced to ISO 1940 standards for extended bearing service life,
- High operating temperature range of −40 °C to +70 °C for windings with insulation class F,* 230 V / 50 Hz single-phase fan motor,
- 400 V / 50 Hz. Three-phase fan motor. Click for the single-phase model.
- Standards-compliant certified components,
- IP 54 Protection Class (IP 55 available on request)
- Three-phase fans can be used with variable frequency drive (VFD) control.
- Motor with external cooling fan for demanding conditions,
Considerations for Fan Selection
Four parameters must be considered when selecting a fan:- Required Air Flow Rate
- Pressure Losses
- Acceptable Noise Level
- Electrical Power Connection Type
| Environment | Air Change Coefficient |
| Auditoriums | 6-8 |
| Paint Ovens | 25-50 |
| Vault Rooms | 3-6 |
| Cinemas and Theaters | 5-8 |
| Commercial Kitchens | 15-30 |
| Foundries | 8-15 |
| Gymnasiums | 4-6 |
| Laundries | 10-20 |
| Indoor Swimming Pools | 3-4 |
| Restaurants | 8-12 |
| Conference Rooms | 6-8 |
| Waiting Rooms | 4-6 |
| Copy Rooms | 10-15 |
| Machine Rooms | 10-40 |
| Shops | 4-8 |
| Dry Cleaning | 5-15 |
| General Manufacturing Areas | 4-8 |
| Hospitals | 8-12 |
| Laboratories | 8-15 |
| Normal Activity (non-smoking) | 29 m³/h |
| Normal Activity (smoking) | 58 m³/h |
| Light Activity | 45 m³/h |
| Heavy Activity (industrial workspaces) | 60 m³/h |
Per-person air volumes in living and working spaces based on activity level can help determine the required air flow rate.
Based on the information provided above, the required air flow rate is determined as follows.
- Q [ m ³ / h ] = Air exchange coefficient (1 h) * Room volume (m ³)
Or
- Q [m³/h] = Number of people × Required airflow per person
Fan selection is made according to this flow rate requirement.
After completing the flow rate calculations, the location where the fan will be installed must be determined. Where will the fan be mounted — on the ceiling, wall, flue, or ventilation duct? Another point to consider is the voltage of the electrical supply to the fan. Since we are using an office as our example, let's continue with that. Fans in offices are generally mounted on a wall or window. If standard domestic power is to be used, a single-phase fan should be preferred. If the installation is in an industrial setting, a fan operating on three-phase (380 V) power should be used.Specifications
| Brand | Dündar |
|---|
Similar products
- Modern Teknik Axial Chimney and Wall Exhaust Fan, 25 cm, 220V, 1,500 RPM, 1,500 m³/h – $203.76
- Nano Water Filter, 1 Inch – $171.69
- Fansan Decorative White Bathroom and Toilet Glass and Window Ventilation Fan – $10.62
- Aircol 20 K Shuttered Axial Fan / Extractor, 360 m³/h – $34.03
- Modern Teknik 0.5 HP Low-Pressure Open-Blade Centrifugal Fan, 45 mmWG, 2,000 m³/h – $485.23
- Aircol 100 mm Duct Inline Round Fan 390 m³/h 2300 rpm - Aircol 100 KF – $48.17
- Raksan Smart ABS Plastic Marine Anemostaat, 100 mm – $4.61
- Dündar MF 280 Axial Fan (EBMPAPST W2E250-HL06-01 Compatible), 280x280x85 mm, 230 V – $94.17
- 65 cm Industrial Pedestal Fan 65 cm – $111.75
- Aircol 150C MP Glass and Wall-Mount Axial Fan – $31.84
More products in Metal-Housing Industrial Exhaust Fan · All Dündar products