Supomp – Water Pumps, Submersible Pumps and Booster Pumps Türkçe

Dündar ST 40S Cooled Industrial Exhaust Fan, Three-Phase, 4,550 m³, 1,450 RPM

$149.70 $207.91 · In stock

Brand: Dündar · SKU: 103404230 · Warranty: 24 months

Dündar ST 40S Cooled Industrial Exhaust Fan, Three-Phase, 4,550 m³, 1,450 RPMDündar ST 40S Cooled Industrial Exhaust Fan, Three-Phase, 4,550 m³, 1,450 RPM

Other options

Product description

Product Type

V

AC/DC

~

Hz

W

Sound

rpm

m3/h

ST 40 S

380

AC

3

50

200

64

1450

4550

MODEL ØA B ØC ØD E F
ST-40S 420 445 475 395 220 125

What Is a Cooling Exhaust Fan?

Fans are equipment that, similar to pumps but unlike them, pressurize and transfer gas rather than liquid. Fans are the most important equipment used not only for the air intake and discharge functions required by industrial processes, but also for the ventilation of residential buildings, workplaces, and especially communal living spaces.
Industrial equipment operating at high levels generally produces excess heat. These systems may carry a risk of overheating if suitable cooling equipment is not used.
Overheated equipment can create a number of risks, including reduced equipment performance, premature component and lubricant degradation, general system failure, and ultimately the possibility of fire and other safety hazards for users and facility personnel. Industrial cooling exhaust fans are fans produced to eliminate these risks. They cool the hot air in your facility while enabling your equipment and personnel to operate more efficiently.

Where Are Cooling Exhaust Fans Used?

  • Warehouses, stockrooms, and storage facilities,
  • Garages and public buildings, agricultural buildings,
  • Commercial greenhouses,
  • Large workshops,
  • Paint shops,
  • Factories,
  • Environments containing dust and vapor,
  • Cooling of industrial machinery (welding machines, transformers, compressors)

Fan Housing and Blade Sections of Cooling Exhaust Fans

  • Cold-drawn, high-quality DKP sheet steel casing and impeller blades,
  • High corrosion resistance with environmentally friendly electrostatic epoxy powder coating,
  • Impeller blades dynamically tested to ISO 1940 standard,
  • Front and rear protection guards conforming to EN 60335-2-80 standards,
  • Slim, compact design with motor and impeller takes up 50% less space than comparable models,
  • Low Noise Level

Motor of Cooling Exhaust Fans

  • High-quality production without manual intervention on high-technology CNC machines,
  • Aluminum-finned motor housing with high thermal conductivity,
  • Rotor balanced to ISO 1940 standards for extended bearing service life,
  • High operating temperature range of −40 °C to +70 °C for windings with insulation class F,* 230 V / 50 Hz single-phase fan motor,
  • 400 V / 50 Hz. Three-phase fan motor. Click for the single-phase model.
  • Standards-compliant certified components,
  • IP 54 Protection Class (IP 55 available on request)
  • Three-phase fans can be used with variable frequency drive (VFD) control.
  • Motor with external cooling fan for demanding conditions,

Considerations for Fan Selection

Four parameters must be considered when selecting a fan:
  • Required Air Flow Rate
  • Pressure Losses
  • Acceptable Noise Level
  • Electrical Power Connection Type
The air change rate required for the space to be ventilated depends on the intended use of the space, the number of people and items inside, and their activity levels. The table alongside shows the recommended air change coefficients for different types of spaces.

Environment Air Change Coefficient
Auditoriums 6-8
Paint Ovens 25-50
Vault Rooms 3-6
Cinemas and Theaters 5-8
Commercial Kitchens 15-30
Foundries 8-15
Gymnasiums 4-6
Laundries 10-20
Indoor Swimming Pools 3-4
Restaurants 8-12
Conference Rooms 6-8
Waiting Rooms 4-6
Copy Rooms 10-15
Machine Rooms 10-40
Shops 4-8
Dry Cleaning 5-15
General Manufacturing Areas 4-8
Hospitals 8-12
Laboratories 8-15
Normal Activity (non-smoking) 29 m³/h
Normal Activity (smoking) 58 m³/h
Light Activity 45 m³/h
Heavy Activity (industrial workspaces) 60 m³/h

Per-person air volumes in living and working spaces based on activity level can help determine the required air flow rate.

Based on the information provided above, the required air flow rate is determined as follows.

  • Q [m³/h] = Air change rate (1 hour) * Room volume (m³)

Or

  • Q [m³/h] = Number of persons × Air flow rate required per person
After determining the required air flow rate for the space, an appropriate duct design should be carried out (taking into account noise and air velocity criteria) and pressure losses should be calculated. Depending on the environment in which the fan will operate, the fan type (axial, radial, roof, smoke exhaust, etc.) should be decided upon, and the appropriate fan should be selected from the relevant fan curve based on the determined flow rate–static pressure pair. To briefly illustrate the above with an example: an office has 5 employees, a ceiling height of 2.6 m, and a floor area of 50 m²; therefore, it has a volume of 2.6 × 50 = 130 m³. The air change rate given for offices in the air change coefficient table is 4–8. Let us take an average of 5. This gives an air requirement of 130 × 5 = 650 m³/h. Assuming normal activity in the office, 5 persons × 29 m³ = 145 m³ of air is needed for the occupants, giving a total air requirement of 650 + 145 = 795 m³/h.

Fan selection is made according to this flow rate requirement.

After completing the flow rate calculations, the location where the fan will be installed must be determined. Where will the fan be mounted — on the ceiling, wall, chimney, or ventilation duct? Another consideration is the voltage of the electrical supply to the fan. Since we used an office as our example, let us continue from there. Fans in offices are generally mounted on the wall or window. If domestic electricity is to be used, a single-phase fan should be preferred. For use in an industrial setting, a fan operating on three-phase (380 V) power should be used.

Specifications

BrandDündar

Similar products

More products in Metal-Housing Industrial Exhaust Fan · All Dündar products