Dündar CST 215.2 Centrifugal Boiler Fan, 2,350 m³, 2,860 RPM
Request a quote: 0531 565 11 25. · Out of stock
Brand: Dündar · SKU: 104162202

Other options
Product description
Applications
- Where the pressure and flow rates of axial fans are insufficient,
- in duct applications,
- In solid-fuel central heating boilers
- Hot air extraction in high-temperature environments, general and industrial buildings,
- Warehouses, stockrooms, and storage facilities,
- Garages and public buildings, agricultural buildings,
- Commercial greenhouses,
- Large workshops,
- Paint shops,
- Factories,
- Environments with dust and vapor,
- Cooling of industrial machinery
GENERALLY USED IN CENTRAL HEATING BOILER FANS.
MIN 60,000 CALL- MAX. 150,000 CALL
Applications:
Where the pressure and flow rates of axial fans are insufficient,
in duct applications,
In solid-fuel central heating boilers
Hot air extraction in high-temperature environments, general and industrial buildings,
Warehouses, stockrooms, and storage facilities,
Garages and public buildings, agricultural buildings,
Commercial greenhouses,
Large workshops,
Paint shops,
Factories,
Environments with dust and vapor,
Cooling of industrial machinery
(Welding machines, transformers, compressors…) *
|
Product Type |
V |
AC/DC |
~ |
Hz |
W |
Sound |
rpm |
m3/h |
|
CST 215.2 |
230 |
AC |
1 |
50 |
1100 |
75 |
2860 |
2350 |
| MODEL | C | E | H | L | O | P | S | T |
| CST 215.2 | 355 | 345 | 366 | 241 | 155 | 125 | 145 | 173 |
CST Series Radial Fan Casing and Impellers;
Radial casing made from cold-drawn high-quality DKP sheet metal. High corrosion resistance with environmentally friendly electrostatic epoxy powder coating. Galvanized forward-curved radial impeller dynamically tested to ISO 1940 standards; high pressure and flow rate values at the inlet nozzle manufactured to EN 60335-2-80 standards. Cage-protected air inlet against foreign matter ingress. Solid and uniform casing structure, low noise level, right- and left-hand orientation options for installation in the desired direction.
CST Series Radial Fan Motors;
Aluminum-finned motor casing with high heat transfer capacity; long bearing service life with a rotor balanced to ISO 1940 standards; high operating range for windings with insulation class F, from −40 °C to +70 °C; 230 V / 50 Hz single-phase fan motor, 400 V / 50 Hz three-phase fan motor; certified components compliant with applicable standards.
Things to Consider When Selecting a Fan;
Four parameters must be considered when selecting a fan.
- Required air flow rate
- Pressure losses
- Acceptable Noise Level
- Electrical Power Connection Type
The air changes required for the space to be ventilated depend on the intended use of the space, the number of occupants and objects inside, and their activities. The table alongside provides the required air change rate coefficients for different environments.
| Environment | Air Change Coefficient |
| Auditoriums | 6-8 |
| Paint ovens | 25-50 |
| Safe rooms | 3-6 |
| Cinemas and theaters | 5-8 |
| Commercial kitchens | 15-30 |
| Foundries | 8-15 |
| Gymnasiums | 4-6 |
| Laundries | 10-20 |
| Indoor swimming pools | 3-4 |
| Restaurants | 8-12 |
| Conference rooms | 6-8 |
| Waiting rooms | 4-6 |
| Photocopier rooms | 10-15 |
| Machine rooms | 10-40 |
| Shops | 4-8 |
| Dry cleaning | 5-15 |
| General manufacturing areas | 4-8 |
| Hospitals | 8-12 |
| Laboratories | 8-15 |
The amount of air per person in living and working spaces depending on activity level can help determine the required air flow rate.
| Air Volume Per Person | |
| Normal activity (non-smoking) | 29 m3/h |
| Normal Activity (smoking) | 58 m3/h |
| Light activity | 45 m3/h |
| Heavy activity (industrial workplaces) | 60 m3/h |
Based on the information provided above, the required air flow rate is determined as follows.
Q [ m3 / h ] = Air exchange coefficient (1 h) * Room volume (m3)
Or
Q [ m3/h ] = Number of persons × Air flow rate required per person
After determining the required air flow rate for the space, a suitable duct design should be made (taking noise and air velocity criteria into account) and pressure losses should be calculated. Depending on the environment in which the fan will operate, the fan type (axial, radial, roof, smoke exhaust, etc.) should be decided upon, and the appropriate fan should be selected from the fan curve based on the determined flow rate–static pressure pair.
To illustrate the above text and table data with an example:
An office has 5 employees, a ceiling height of 2.6 m, and a floor area of 50 m2, giving a volume of 2.6 × 50 = 130 m3. The air change rate from the table for an office is 4–8; let us take 5.
130 × 5 = 650 m3/h air requirement from the space. Assuming normal activity in the office, 5 persons × 29 m3 = 145 m3 air requirement for the occupants, giving a total of 650 + 145 = 795 m3/h air requirement.
Fan selection is also made based on this flow rate requirement.
After completing the flow rate calculations, the installation location of the fan should be determined. Where will the fan be mounted — ceiling, wall, chimney, or ventilation duct? Another consideration is the voltage of the electrical supply to the fan. Continuing with our office example: fans in offices are generally mounted on a wall or glass. If a domestic electricity supply is used, a single-phase fan should be preferred. If it is to be used in an industrial setting, a fan operating on three-phase (380 V) power should be used.
Specifications
| Brand | Dündar |
|---|
Similar products
- Modern Teknik Axial Chimney and Wall Exhaust Fan, 25 cm, 220V, 1,500 RPM, 1,500 m³/h – $203.76
- Nano Water Filter, 1 Inch – $171.69
- Fansan Decorative White Bathroom and Toilet Glass and Window Ventilation Fan – $10.62
- Aircol 20 K Shuttered Axial Fan / Extractor, 360 m³/h – $34.03
- Modern Teknik 0.5 HP Low-Pressure Open-Blade Centrifugal Fan, 45 mmWG, 2,000 m³/h – $485.23
- Aircol 100 mm Duct Inline Round Fan 390 m³/h 2300 rpm - Aircol 100 KF – $48.17
- Raksan Smart ABS Plastic Marine Anemostaat, 100 mm – $4.61
- Dündar MF 280 Axial Fan (EBMPAPST W2E250-HL06-01 Compatible), 280x280x85 mm, 230 V – $94.17
- 65 cm Industrial Pedestal Fan 65 cm – $111.75
- Aircol 150C MP Glass and Wall-Mount Axial Fan – $31.84
More products in Boiler Fans for Central Heating · All Dündar products