Fire Pumps

Electric and diesel fire booster sets for building and facility fire systems: single-, twin-, and triple-pump sets with jockey pump. Request a quote tailored to your project.

Products (3)

Brands: Nortek · Sumak

What is a fire pump?

Fire pumps are pump groups that supply water at the required flow rate and pressure to sprinkler, fire cabinet, and hydrant systems in the event of a fire. A fire set typically consists of the main pump or pumps, a small jockey pump that continuously maintains system pressure, a control panel, manifolds, valves, and a pressure tank. The main pump can be electric-motor-driven or diesel-engine-driven; diesel-powered sets are preferred to guard against the risk of power failure.

Set types

The category includes fire booster sets from Sumak and Nortek in various capacities.

How is selection made?

Fire pump selection is based on a design calculation performed according to criteria such as the building's intended use, hazard class, and number of sprinklers and hydrants. Selection must therefore be carried out by a qualified plumbing engineer in accordance with the Regulation on the Protection of Buildings from Fire and the relevant standards. The flow rate (m³/h) and pressure (m) values are taken from the project report to determine the appropriate set. The capacity of the fire storage tank to be used as a water source is also part of this calculation.

Frequently asked questions

What does a jockey pump do?

It compensates for minor pressure drops in the system, keeping it continuously pressurized. This way, the main pump activates only when there is a real demand for water.

Can a fire pump be used in place of a regular booster pump?

No. Fire sets are designed exclusively for fire suppression systems and must be kept separate from domestic water systems.

What information is needed for a quote?

You can request a quote by providing the flow rate and pressure values from the project report, the required number of pumps, and the drive type (electric or diesel).

How is a fire set maintained?

Routine test runs, fuel and battery checks on diesel engines, and panel and sensor inspections must be carried out by qualified personnel.

What power supply does a fire pump operate on?

Electric fire pumps are typically three-phase powered and connected via a dedicated line to ensure uninterrupted power. Diesel pump sets provide additional protection against power outages.